选择语言

Recombinant Factor C Endotoxin Detection Kit

用户评价
货号-规格
价格
Qty.
RES-A056-96tests
¥2940.00
RES-A056-48tests
¥1600.00
合计0件 产品金额¥ 0

产品详情

    1. Comparable to LAL method - Endpoint fluorescent assay, comparable to other chromogenic quantitative LAL methods.
    2. High specificity - Unlike LAL Assay, as Factor G is absent from the rFC test kit, false-positive results due to β-glucan activation are not expected to occur.
    3. Accuracy - Traceability of endotoxin standards in the kit against USP Standard (Catalog No: 1235503).
    4. Fast time to results - 1 hours.
    5. High sensitivity - Sensitivity range from 0.005-5 EU/mL.
    6. Extensive validation – Verification on multiplex biological products, kinds of microplate readers and various buffer systems, comprehensive validation of specificity, sensitivity, precision, accuracy, applicability, and other aspects according to the parameters listed in the EUROPEAN PHARMACOPOEIA 11.0 and USP chapter<<1225>>.
    7. Sustainable resource - Get rid of dependence on animal derived reagents, reduce dependence on horseshoe crab resources and fishing pressure and realize long-term supply.
    8. Good inter batch consistency - Batch consistency of products is guaranteed due to the use of genetic recombination technology for production.
  • 重组C蛋白:拯救鲎宝贝,共创绿色未来

    Endotoxin PRODUCT Impression
  • 背景(Background)

    The Recombinant Factor C Endotoxin Detection Kit is a novel endotoxin detection method based on the recombination technology. Recombinant Factor C, as the first component of the horseshoe crab coagulation cascade reaction, is activated by an endotoxin. The activated Factor C can cleave the fluorogenic substrate and produce a fluorescent signal. The increase of fluorescence signal is positively correlated with the dosage of endotoxin. The experiment is carried on a white 96-well plate and is measured at time zero and after a one-hour 37℃ incubation. Use a fluorescence microplate reader to measure at the wavelength of ex/em = 380/440 nm to determine whether the sample is contaminated by endotoxin.

  • 原理(Assay Principles)

    The Recombinant Factor C Endotoxin Detection Kit is a novel endotoxin detection method based on the recombination technology. Recombinant Factor C, as the first component of the horseshoe crab coagulation cascade reaction, is activated by an endotoxin. The activated Factor C can cleave the fluorogenic substrate and produce a fluorescent signal. The increase of fluorescence signal is positively correlated with the dosage of endotoxin. The experiment is carried on a white 96-well plate and is measured at time zero and after a one-hour 37℃ incubation. Use a fluorescence microplate reader to measure at the wavelength of ex/em = 380/440 nm to determine whether the sample is contaminated by endotoxin.

    Assay Principles

  • 产品描述(Product Details)

    Assay Type
    FRET
    Analyte
    Endotoxin
    Format
    48T, 96T
    Regulatory Status
    RUO
    Sensitivity
    0.005 EU/mL
    Standard Curve Range
    0.005 EU/mL-5 EU/mL
    Assay Time
    1 hr
    Suitable Sample Type
    For the quantitative determination of endotoxin from pharmaceutical products, biologicals for injection and some media for tissue cultures.
    Sample volume
    100 μL

  • 组分(Materials Provided)

    ID
    Components
    Size
    RES056-C01
    Bacterial Endotoxin Standard
    1 vial
    RES056-C02
    Recombinant Factor C Protein
    48 tests/96 tests
    RES056-C03
    Fluorogenic Substrate
    48 tests/96 tests
    RES056-C04
    Water for Bacterial Endotoxins Test
    50 mL

  • 应用说明(Application)

    Production process (Process control)
    1. Raw materials
    2. Water testing
    3. Intermediate product testing
    Final product (Release testing)
    1. Parenteral drugs & Biological products
    2. Infusion, injection or tranfusion cells
    3. Cell culture media
    4. Medical devices

    It is for research use only.

  • 存储(Storage)

    2-8℃

  • 质量管理控制体系(QMS)

    1. 质量管理体系(ISO, GMP)
    2. 质量优势
    3. 质控流程

产品展示

  • 活性(Bioactivity)-Fluorescence

    Please refer to DS document for the assay protocol.

     Endotoxin FLUORESCENCE

    Take the logarithm of the concentration of the Endotoxin working standard solution as the abscissa, take the ΔRFU as the ordinate. Fitting the standard curve with linearly model, and the correlation coefficient R should be ≥ 0.98 (QC tested).

  •  Endotoxin FLUORESCENCE

    The rFC method was employed to detect endotoxin residues in β-glucan at concentrations of 10ug/mL and 1ug/mL. No non-specific signals were detected. In contrast, the dynamic chromogenic method used for β-glucan detection resulted in the detection of endotoxin and non-specific signals. This indicates that recombinant factor C does not react with β-glucan, demonstrating the good specificity of the rFC method.

用户评价
发表评论

前沿进展

 
联系我们
项目合作
查看更多项目
  • 产品SKU
  • 产品详情
  • 产品展示